Architecture Faculty of Tournai

Country

Belgium

Architecture

Aires Mateus

Photography

Tim Van de Velde

About the project

In Tournai, Belgium, Aires Mateus is redefining academic architecture with the Faculty of Architecture, a project that goes beyond traditional educational buildings. The structure is a learning space and an architectural statement designed to inspire creativity and openness. Aires Mateus focused on geometric purity and material simplicity to create spaces that encouraged contemplation and interaction.

For this project, OTIIMA provided custom-made glazing solutions tailored to the building’s modern aesthetic and functional needs. Our systems’ transparency and adaptability support the creation of shared spaces that feel open and intimate.

Welcome

You already have an account please? Login

First Name*
Last Name*
Email*
Password*
Password
Country*
Job Title*
Company*
First Name*
Last Name*
Email*
Password*
Password
Country*
Job Title*
Company*
Website*
Years in business*
Message*

Newsletter

OTIIMA - Much more than a window

Subscribe





    Compare products

    Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

    thermal-transmittance

    Thermal Transmittance

    watertightness

    Watertightness

    air-permeability

    Air permeability

    wind-resistance

    Wind resistance

    resistance

    Impact resistance

    insulation

    Sound insulation

    security

    Security

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 0.7 (38mm)
    Uw Ug = 0.7 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    Class 8A

    (450 Pa or 95 km/h)

    air-permeability

    Air permeability

    ISO EN 12207 + ISO en 1026

    Class 3

    (600 Pa or 110 Km/h)

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (2000 Pa or 200 Km/h)

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5

    (in 6 possible classes)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 38 db (up to)
    security

    Security

    RC2: (WK2) 2

    RC2: (WK2)
    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1,0 (38mm)
    Uw Ug = 0.5 (54mm)
    Uw Ug = 0.47 (62mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1200

    (7 classes above 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO en 1026

    Class 4

    (600 Pa or 110 Km/h) 1

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class B5

    (2000 Pa or 200 Km/h) 1

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5 (38mm / 54mm)

    1C1 | 2B2 | 1B1 2 (62mm)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to) (38mm / 54mm)

    Rw: 44 db (up to) (62mm)

    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    3

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1,0 (38mm)
    Uw Ug = 0.5 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1200 (54mm)

    (4 classes above 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO EN 1026

    Class 4

    (600 Pa or 119 Km/h) 1 2

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (in 6 possible classes) 2

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5

    (2000 Pa or 200 Km/h)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to)
    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    3

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1.0 (38mm)
    Uw Ug = 0.5 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1650

    (7 Clases superior a 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO EN 1026

    Class 4

    (600 Pa or 110 Km/h) 1

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (2000 Pa or 200 Km/h) 1

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5
    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to)
    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    2