1615 House

Country

Spain

Architecture

Nordest Arquitectura

Photography

Filippo Poli

About the project

Situated within the picturesque landscapes of Costa Brava, Spain, the 1615 House represents a contemporary architectural achievement that redefines the interplay between structure and the natural environment. This modern structure transcends traditional design principles by merging indoor and outdoor environments while framing the region’s vistas. The stepped cascade design, developed in response to the site’s steep topography, converts a potential limitation into a unique opportunity, allowing the building to blend effortlessly with its surroundings. From the initial point of arrival at the rooftop, the visitor’s experience is characterized by fluidity, openness, and a deep connection with the natural setting.

A key aspect of the house is its inventive application of materials and joinery. Sculptural concrete volumes encapsulate the living spaces, featuring strategically positioned openings complemented by large natural wood sliding doors. This design fosters a dynamic interplay of light, air, and space, empowering residents to tailor their living environment. Supporting this cohesive design concept, OTIIMA’s Fusion System provides an invisible, frameless glazing solution that enhances the minimalist aesthetic while preserving unobstructed panoramic views.

Welcome

You already have an account please? Login

First Name*
Last Name*
Email*
Password*
Password
Country*
Job Title*
Company*
First Name*
Last Name*
Email*
Password*
Password
Country*
Job Title*
Company*
Website*
Years in business*
Message*

Newsletter

OTIIMA - Much more than a window

Subscribe





    Compare products

    Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

    thermal-transmittance

    Thermal Transmittance

    watertightness

    Watertightness

    air-permeability

    Air permeability

    wind-resistance

    Wind resistance

    resistance

    Impact resistance

    insulation

    Sound insulation

    security

    Security

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 0.7 (38mm)
    Uw Ug = 0.7 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    Class 8A

    (450 Pa or 95 km/h)

    air-permeability

    Air permeability

    ISO EN 12207 + ISO en 1026

    Class 3

    (600 Pa or 110 Km/h)

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (2000 Pa or 200 Km/h)

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5

    (in 6 possible classes)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 38 db (up to)
    security

    Security

    RC2: (WK2) 2

    RC2: (WK2)
    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1,0 (38mm)
    Uw Ug = 0.5 (54mm)
    Uw Ug = 0.47 (62mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1200

    (7 classes above 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO en 1026

    Class 4

    (600 Pa or 110 Km/h) 1

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class B5

    (2000 Pa or 200 Km/h) 1

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5 (38mm / 54mm)

    1C1 | 2B2 | 1B1 2 (62mm)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to) (38mm / 54mm)

    Rw: 44 db (up to) (62mm)

    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    3

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1,0 (38mm)
    Uw Ug = 0.5 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1200 (54mm)

    (4 classes above 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO EN 1026

    Class 4

    (600 Pa or 119 Km/h) 1 2

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (in 6 possible classes) 2

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5

    (2000 Pa or 200 Km/h)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to)
    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    3

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1.0 (38mm)
    Uw Ug = 0.5 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1650

    (7 Clases superior a 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO EN 1026

    Class 4

    (600 Pa or 110 Km/h) 1

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (2000 Pa or 200 Km/h) 1

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5
    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to)
    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    2