Mies van der Rohe

Five Lessons from Mies van der Rohe for Architects Today

March 27 marks the anniversary of Ludwig Mies van der Rohe, one of the most influential architects of the 20th century. His philosophy, built on clarity, simplicity, and material honesty, inspires contemporary architecture. His work embodies a timeless vision that remains as relevant as ever. Here are five key lessons architects today can learn from Mies van der Rohe.

Less is More

Perhaps his most famous principle, “Less is more,” summarizes Mies’ approach to design: stripping away the unnecessary to reveal the essential. His buildings are characterized by clean lines, open floor plans, and an absence of ornamentation. This philosophy encourages architects to prioritize spatial clarity and material integrity, resulting in modern and enduring structures.

The Farnsworth House / Mies van der Rohe

Honesty in Materials

Mies believed that materials should be celebrated for what they are rather than being disguised. Whether it was steel, glass, or concrete, he used each material to its full potential, allowing its natural properties to define the architecture. This approach reinforces a sense of authenticity and permanence, which inspires today’s architects to embrace material honesty in their projects.

Lafayette Park / Mies van der Rohe

Blurring the Boundary Between Indoors and Outdoors

One of Mies’ most significant contributions to architecture is his seamless integration of indoor and outdoor spaces. Projects like the Farnsworth House demonstrate his mastery of transparency and openness, dissolving the boundary between built and natural environments. This lesson is especially pertinent today, as architects seek to design spaces that enhance well-being by connecting occupants with nature.

The Farnsworth House / Mies van der Rohe

The Power of Proportion and Precision

Mies was meticulous in his attention to detail, ensuring that every element of his buildings was carefully proportioned and aligned. His mastery of grids, symmetry, and precision created a sense of order and harmony. This discipline remains crucial for architects today, particularly when designing minimalist spaces where every detail is carefully considered.

Neue Nationalgalerie / Mies Van der Rohe

Timelessness Through Simplicity

Mies’ designs have an enduring quality because they are rooted in simplicity. His buildings, from the Barcelona Pavilion to the Seagram Building, remain as striking today as they were decades ago. The ability to create architecture that transcends trends is a valuable lesson—by focusing on pure forms, honest materials, and spatial clarity, architects can design structures that stand the test of time.

Barcelona Pavilion / Mies van der Rohe

Mies van der Rohe’s principles continue to guide contemporary architects. His vision of simplicity, material integrity, and architectural balance continues to influence design worldwide. As we celebrate his legacy, these lessons remind us that great architecture is not about complexity but about achieving perfection through simplicity.

Welcome

You already have an account please? Login

First Name*
Last Name*
Email*
Password*
Password
Country*
Job Title*
Company*
First Name*
Last Name*
Email*
Password*
Password
Country*
Job Title*
Company*
Website*
Years in business*
Message*

Newsletter

OTIIMA - Much more than a window

Subscribe





    Compare products

    Compare products easily by analyzing features and specifications side by side to find the best option for your needs.

    thermal-transmittance

    Thermal Transmittance

    watertightness

    Watertightness

    air-permeability

    Air permeability

    wind-resistance

    Wind resistance

    resistance

    Impact resistance

    insulation

    Sound insulation

    security

    Security

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 0.7 (38mm)
    Uw Ug = 0.7 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    Class 8A

    (450 Pa or 95 km/h)

    air-permeability

    Air permeability

    ISO EN 12207 + ISO en 1026

    Class 3

    (600 Pa or 110 Km/h)

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (2000 Pa or 200 Km/h)

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5

    (in 6 possible classes)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 38 db (up to)
    security

    Security

    RC2: (WK2) 2

    RC2: (WK2)
    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1,0 (38mm)
    Uw Ug = 0.5 (54mm)
    Uw Ug = 0.47 (62mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1200

    (7 classes above 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO en 1026

    Class 4

    (600 Pa or 110 Km/h) 1

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class B5

    (2000 Pa or 200 Km/h) 1

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5 (38mm / 54mm)

    1C1 | 2B2 | 1B1 2 (62mm)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to) (38mm / 54mm)

    Rw: 44 db (up to) (62mm)

    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    3

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1,0 (38mm)
    Uw Ug = 0.5 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1200 (54mm)

    (4 classes above 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO EN 1026

    Class 4

    (600 Pa or 119 Km/h) 1 2

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (in 6 possible classes) 2

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5

    (2000 Pa or 200 Km/h)

    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to)
    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    3

    thermal-transmittance

    Thermal Transmittance

    Uw Ug = 1.0 (38mm)
    Uw Ug = 0.5 (54mm)

    watertightness

    Watertightness

    ISO EN 12208 + ISO EN 1027

    E1650

    (7 Clases superior a 9A) 1

    air-permeability

    Air permeability

    ISO EN 12207 + ISO EN 1026

    Class 4

    (600 Pa or 110 Km/h) 1

    wind-resistance

    Wind resistance

    ISO EN 12210 + ISO EN 12211

    Class C5

    (2000 Pa or 200 Km/h) 1

    resistance

    Impact resistance

    ISO EN 12600 + ISO EN 1630

    Class 5
    insulation

    Sound insulation

    ISO EN 10140 + ISO EN 717

    Rw: 42 db (up to)
    security

    Security

    ISO EN 1628 + ISO EN 1629 + ISO EN 1630

    RC2: (WK2)

    2